DIRECT DRIVE VALVES, PROPORTIONAL VALVES & SERVOVALVES

Test bench rental

FACT can provide you develop tests mean in order to perform your tests :

Performance of our tests benchs/means are as follow :

 

1. Fuel test bench (1 inlet and3 outlets)

Hydraulic power :

  • 1600L/H@70 bar pump (JET A or MIL PRF 23699) ATEX.

  • Cooling circuit

Measuring, data acquisition and control:

  • 3 Coriolis effect flowmeters (1 on an inlet et 2 on an equipment outlets)

    • ±0,1% of mesured value

  • 3 Pressure sensors

    • ±0,1% of full scale

  • Autonomous endurance test possible

  • Control and datas acquisition with Labview equipment

 

 

2. Air test bench air (1 inlet and 1 outlet)

Pneumatic Power :

  • 50g/s @2.5 bar air Compressor 50g  ( Ambiant air).

  • Air heater up to 250°C

  • Measuring, data acquisition and control:

    • 1 Coriolis effect flowmeter

      • ±0,1% of mesured value

    • 3 Pressure sensors

      • ±0,1% of full scale

    • Autonomous endurance test possible

    • Control and datas acquisition with Gantnerr Instrument

3. Oil test bench (1 inlet and3outlets)

Hydraulic power :

  • 15000l/H @70 bar pump (MIL-PRF-23699).

  • Pompe 15000l/h@ 70 bar (MIL-PRF-23699).

  • Oil heater 160°C

  • Oil Cooling up to -42°C

Measuring, data acquisition and control:

  • 3 Coriolis effect flowmeters (1 on an inlet et 2 on an equipment outletS) ±0,1% of mesured value

  • 7 Pressure sensors 1.±0,1% of full scale

  • Autonomous endurance test possible

  • Control and datas acquisition with Gantnerr Instrument

4. Climatic chamber for operating and not operating equipment test

  • Temperature controlled [ -72°C; +180°C ] 

  • Heat variation 4°C/min

  • Cooling variation 3°C/min

  • 180 liters tests volumes (550mm Large, 740mm Heigh, 420mm depth)

5. Azote test bench

  • 1 azote compressed bottle

  • A set of 3 valves and 2L tank set in order to mesure equipment leakage.

 

6. Oil and fuel pollution tests bench

  • 1200l/h@ 280 bar  pump (Fluid JET A1)

  • Precise setting of outlet pump pressure

  • Oil heating up to 140°C

  • Polluant injecting up Ø1mm

  • Easily movable

7. Dilectric and milliohmeter

  • Breakdownvoltage

       • Measuring range : [0.01mA – 10mA] for 5kV AC or 6kV DC max supply

  • Insulation between active and not-active material

       • Measuring range: [50kW – 200GW] for 10V to 500V DC max supply

  • Mass resistance measurement between the different exterior not-active part of the equipement

       • Measuring range: [1mW - 6kW] for 1mA to 5A supply